Proposti limiti SAR più prudenziali per esposizione da telefono cellulare
Due ricercatori dell'Environmental Working Group (associazione ambientalista USA) hanno pubblicato su una rivista Environmental Health (altamente quotata a livello internazionale) limiti di esposizione da telefono cellulare
Partendo dai dati pubblicati dallo studio NTP (cardiopatie) loro propongono un limite di sicurezza espresso in SAR sull'intero corpo pari a 0,002 - 0,004 W/Kg contro lo 0,08 W/Kg ammessi nella UE (Raccomandazione Consiglio Europeo 1999/519/Ec !
Uloma Igara Uche, Olga V Naidenko. Development of health-based exposure limits for radiofrequency radiation from wireless devices using a benchmark dose approach. Environ Health 20, 84 (2021). doi: 10.1186/s12940-021-00768-1.
Abstract
Background Epidemiological studies and research on laboratory animals link radiofrequency radiation (RFR) with impacts on the heart, brain, and other organs. Data from the large-scale animal studies conducted by the U.S. National Toxicology Program (NTP) and the Ramazzini Institute support the need for updated health-based guidelines for general population RFR exposure.Objectives The development of RFR exposure limits expressed in whole-body Specific Absorption Rate (SAR), a metric of RFR energy absorbed by biological tissues.
Methods Using frequentist and Bayesian averaging modeling of non-neoplastic lesion incidence data from the NTP study, we calculated the benchmark doses (BMD) that elicited a 10% response above background (BMD10) and the lower confidence limits on the BMD at 10% extra risk (BMDL10). Incidence data for individual neoplasms and combined tumor incidence were modeled for 5% and 10% response above background.
Results Cardiomyopathy and increased risk of neoplasms in male rats were the most sensitive health outcomes following RFR exposures at 900 MHz frequency with Code Division Multiple Access (CDMA) and Global System for Mobile Communications (GSM) modulations. BMDL10 for all sites cardiomyopathy in male rats following 19 weeks of exposure, calculated with Bayesian model averaging, corresponded to 0.27–0.42 W/kg whole-body SAR for CDMA and 0.20–0.29 W/kg for GSM modulation. BMDL10 for right ventricle cardiomyopathy in female rats following 2 years of exposure corresponded to 2.7–5.16 W/kg whole-body SAR for CDMA and 1.91–2.18 W/kg for GSM modulation. For multi-site tumor modeling using the multistage cancer model with a 5% extra risk, BMDL5 in male rats corresponded to 0.31 W/kg for CDMA and 0.21 W/kg for GSM modulation.